| Name | CV Elite – Titanium Debakey Micro Clamp – Angled Jaws |
| Lead Time | LEAD TIME ADVISED WITHIN 48 HOURS OF ORDER PLACEMENT. |
| Specialty | Cardiothoracic-Clamps-Titanium Vascular Clamps – Delicate Clamps |
| Material Finish | Titanium |
| Grade | Premium Operating Room |
| Units of Measurement | Each |
| Manufacturer | Tool Tectra |
| Sterility | Non-Sterile |
| Usage | Reusable |
Titanium Debakey Micro Clamp – Angled Jaws
Titanium Debakey Micro Clamp – Angled Jaws
angled debakey jaws.
Titanium DeBakey Micro Clamp is most often used for cardiovascular surgeries to clamp smaller vessels. The clamp’s titanium composition makes it extremely lightweight and strong, so as to reduce strain on the surgeon’s hand, in addition to making it non-magnetic. Numerous jaw angle and instrument lengths are offered to accommodate various procedures, and all versions feature DeBakey serrated jaws for atraumatic clamping.
SKU:
TT-SI-8615
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Titanium Debakey Micro Clamp – Angled Jaws” Cancel reply
Shipping & Delivery
Related products
Cooley Aortic Aneurysm Clamp
SKU:
TT-SI-2373
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Cooley Patent Ductus Clamp – 6 1/4″
SKU:
TT-SI-2718
Cooley Patent Ductus Clamp - 6 1/4"
jaws calibrated at 5.0 mm intervals, 6-1/4" (16.0 cm)
Cooley Patent Ductus clamp is well suited for use in cardiothoracic surgical procedures. Specifically this clamp is designed for use in surgical procedures to repair a patent ductus. The jaws of this clamp are calibrated at 5 mm intervals and are designed for a firm surgical grip upon the vessels but is delicate enough to prevent any bruising or tears to the vessels walls themselves. This instrument is available with either straight or angular shanks making it possible to select the best fit possible for the procedure at hand.
Cooley Neonatal Clamp
SKU:
TT-SI-2712
Cooley Neonatal Clamp
5" (12.5 cm)
Cooley Neonatal Clamp is the ideal tool for use in surgical procedures for newborn children. This clamp is build sturdily but made small enough to clamp the delicate vessels of a newborn child. This instrument is particularly well suited due to its ability to maintain a hold on the vessel without causing tears or rip on the delicate vessel walls of the newborn. Additionally, this clamp is available in a straight profile, spoon jawed, anastomosis clamp, carotid clamp or angled shank and straight jaws or curved shanks and angled jaws.
Calman Carotid Clamp
SKU:
TT-SI-5646
Calman Carotid Clamp
angled shanks, long thin jaw, 25.0 mm, 4-1/4" (11.0 cm)
Calman Carotid Clamp is ideally suited for use in cardiothoracic surgical procedures specifically in surgeries that require clamping of the carotid vessels. This clamp feature angled shanks to increase the easy of access to the vessels as well as having a long thing jaw that allows it to move between deeper layers of tissue without displacing anything or injuring other organs of vasculature. This clamp is strong enough to provide the occluding force necessary but also is gentle enough to keep the carotid walls intact with minimal injury or bruising.
Beck Miniature Aorta Clamp – Stainless
SKU:
TT-SI-1882
Beck Miniature Aorta Clamp - Stainless
straight shanks, 6-3/4" (17.0 cm), debakey jaws, stainless
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Cleveland Clinic Renal Clamp
SKU:
TT-SI-7857
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.
Cooley Caval Occlusion Forceps
SKU:
TT-SI-7426
Cooley Caval Occlusion Forceps
8-1/4" (21.0 cm)
Cooley Caval Occlusion Forceps are specially designed vascular clamps for use in cardiothoracic surgical procedures. This instrument is designed with ring handles for ease in maneuvering and opening and closing and also a ratcheting mechanism to hold the forceps at a particular tightness. The most unique feature of these forceps is that each jaw features a half circle projection outwards which when the jaw is brought together forms a complete circular opening as well as the fact that the entire instrument is formed in a crescent type shape. This instrument is available with a number of different diameters to the opening in the jaws in 2 fr. Increments from 24 – 40 fr.
Cooley Auricular Appendage Forceps
SKU:
TT-SI-2552
Cooley Auricular Appendage Forceps
1-5/8" x 3/8" (4.1 cm x 1.0 cm) jaws, 10" (25.4 cm)
Cooley Auricular Appendage Forceps are specially designed for use in cardiothoracic surgical procedures. These forceps have a wide application but are particularly well suited for use in manipulating auricular appendages. Each auricle leads into its respective atrium and thus this instrument is of use in surgical procedures that require access to the atria. The scissor handle grip allows for ease in grasping and manipulating this tool.

Reviews
There are no reviews yet.